What are common problems with automatic doors?
In 2026, Handyman Algarve quotes the servicing and repair of automatic doors for hotels, shops, clinics and buildings of flats in the Algarve, and the problems those doors show come from their parts: the sensors, the floor guide, the mode selector, the supply, the drive and the lock. On an automatic door that misbehaves, a manager can check the mode selector and anything in front of the sensors and, with the door switched off at the board and the backup battery disconnected where one is fitted, the floor guide, which is left to the technician where the battery sits under the operator cover. An automatic door that moves when it should not, or does not stop or reverse for a person, comes out of use at once. An automatic door that people use to leave a building is never left locked shut while the building is occupied without another exit open.
In 2026, Handyman Algarve quotes the servicing and repair of automatic doors for hotels, shops, clinics and buildings of flats in the Algarve. The problems an automatic door shows come from its parts: the sensors that open it and watch its path, the track above the opening and the floor guide below it, the mode selector, the supply and the backup battery, the drive, and the lock. A door that will not open, will not close, opens for nobody, stops part way, grinds, bangs or will not lock is pointing at one of them.
A manager’s checks stay at floor level and leave the door’s covers closed: the mode selector, the field in front of the sensors, the door’s breaker at the board and the floor guide. Everything else is a technician’s, and some symptoms mean the door comes out of use before anything is looked at.
When does an automatic door have to come out of use?
At once, when it moves when it should not, does not stop or reverse for a person in its way, closes too fast or bangs, and when a leaf has dropped, come out of its floor guide or cracked. Those are faults in what keeps people safe around a moving door, and its hazards sit where it moves: the closing edges, the gaps between a moving leaf and the frame or a fixed panel, the hinge side of a swing door and the wings of a revolving door. In this order:
- Stop using it and keep people clear of the doorway, the closing edges and the hinge side, and of the wings of a revolving door.
- Put it out of service with its own mode selector or key switch, if it has one, on the setting its manual gives for that.
- If it has none, or does not obey it, switch it off at the board, at the door’s breaker, and disconnect the backup battery, where one is fitted, as the manual shows. On battery, the door can still move, and a door set to open by itself when the power fails can move as the breaker goes off. Where the battery sits inside the operator, under its cover, it is left to the technician, and people are kept clear of the door until the technician has seen it.
- If people use the door to leave the building, keep a way out open. A door on an escape route is never left locked shut or out of action while the building is occupied without another exit open: it is left open, where security allows, or another way out is kept open and signed, and the person who holds the building’s fire-safety documents is told.
- Then call, with what the door did and when.
While the door waits for the technician:
- Hands stay away from the drive. Nobody puts a hand near the belt, the pulleys or the carriages under the operator cover, the cover stays closed, and nobody climbs a ladder to the operator or to a sensor.
- No sensor is bridged, covered, taped or disconnected to keep the door running. Disabling a sensor to get a door moving again is not a temporary fix: it leaves the door free to close on whoever is in its way.
- A revolving door is never forced round by hand against its drive.
- A leaf that has dropped or come out of its guide is not lifted or pushed back into place. A glass leaf is heavy, and one that is off its carriage or out of its guide can swing or fall.
In a building of flats, a fault on the entrance door goes to the building’s administrador, who arranges the call-out for the condominium; the steps above are the same while it waits. A car park barrier or a rising bollard has rules of its own on site, above all when its boom is broken or bent: see staying safe around a car park barrier or a rising bollard.
What is behind each problem, and what can a manager check?
Each symptom points to a class of cause in the door’s engineering. A manager makes only the checks in the third column, from the floor, with the operator cover closed and no ladder. When a check does not clear the fault, or the fault comes back, the door is the technician’s.
| What the door does | What can be behind it | What a manager may check | When to stop and call |
|---|---|---|---|
| Will not open for people approaching | The mode selector on another setting, such as closed, locked or exit only; no supply at the board; an activation sensor blocked, dirty or knocked out of line; the lock; the control unit | The selector’s setting; whether the door’s breaker at the board is on; anything standing in front of the sensor | When the selector is on automatic, the breaker is on and the door stays shut. A breaker that has tripped is left off and reported: the supply is an electrician’s work |
| Stays open or will not close | Something in the doorway or the sensors’ field, such as a sign, a display, a plant or a mat whose edge has lifted; the selector set to held open; a safety sensor dirty or knocked out of line; something in the floor guide | The selector’s setting; anything in the doorway or in front of the sensors; the floor guide, as below | When it stays open with the doorway and the field clear and the selector on automatic |
| Opens when nobody is coming | Something moving in the activation sensor’s field, such as a flag, a sign or a plant moved by a draught, or people passing along the frontage; a sensor knocked out of line | What moves in front of the door, and moving it away | When it keeps opening with nothing in the field: the field is the technician’s to set |
| Closes on a person, or does not stop or reverse for one | A safety sensor dirty, blocked, knocked out of line or failed; the control unit or its settings | Nothing: the door comes out of use at once, as above | Straight away |
| Stops part way, sticks or runs unevenly | Something in the floor guide or the track; wear in the carriage wheels, the belt or the floor guide; a leaf rubbing on the floor or the frame; on a swing door, the arm | The floor guide, as below | When it still sticks with the guide clear |
| Grinds, squeals, knocks or rattles | Wear in the drive: the belt, the pulleys, the carriage wheels, the motor and its gearbox; fixings working loose | Nothing inside: note when the noise comes, and film it from outside the door’s path | When the noise starts; the operator cover stays closed |
| Bangs open or shut, or closes too fast | The control unit’s settings; wear in the drive; a carriage, an arm or a fixing working loose | Nothing: the door comes out of use at once, as above | Straight away |
| Will not lock, or stays locked | The selector on another setting; the leaves not fully closed because something holds them in the floor guide; the lock or its control | The selector’s setting; the floor guide, as below | When the selector is right and the leaves close fully but the lock does not work |
| Dead after a power cut | The supply not back at the board, or a breaker that has tripped; the control unit waiting for the restart its manual gives | Whether the breaker at the board is on, a tripped one left off and reported; the selector; the restart in the manual, as below | When the restart does not bring it back, or the fault returns |
| Shows a fault light or a code | The control unit reporting a fault it has found | Write the code down and look it up in the manual; the manual’s own reset | When the code comes back after a reset |
| A revolving door stops or will not turn | A stop button pressed, where the door has one; a safety sensor or edge that has seen something; the drive | The selector; whether a stop button has been pressed, and the manual’s way of resetting it; nothing caught at the wings | When it will not run: the wings are never forced round by hand against the drive |
A door that will not open, or stays locked, on a way out of an occupied building is the escape-route case above: another way out is kept open and signed, and the person who holds the building’s fire-safety documents is told, before anything else.
How does a manager check the floor guide safely?
The floor guide holds the bottom of a sliding leaf in line as it runs, and grit, sand, a stone, a coin or a door wedge in it is enough to stop or slow a leaf. In this order:
- The door stopped, with nobody in the doorway.
- The power off at the board, at the door’s breaker, and the backup battery disconnected, where one is fitted. On battery, the door can still move, so where the battery sits under the operator cover, the floor guide is left to the technician. A door set to open by itself when the power fails can move as the breaker goes off.
- The guide and the threshold cleared with a brush or a vacuum nozzle, not with fingers, and nobody pushing the leaves meanwhile.
- The power back on as the manual describes, the selector back to automatic, and the next openings watched with people kept clear.
- If the door still sticks, it comes out of use and the technician is called.
Can a manager clean or adjust the sensors?
No: a sensor is cleaned, aimed and tested by the technician, and never from a ladder. Its field decides when the door opens and keeps it from closing on a person, so a sensor that has been knocked, turned or adjusted by hand is set again and tested before the door is relied on. What a manager can do is keep that field clear: no sign, display, plant, hanging decoration or lifted mat in front of the door, and no wedge in its path.
How do I reset my automatic door?
With the reset its own manual gives, and only for a door that has stopped or shows a fault code. A door that closed on someone, did not stop or reverse, or bangs is not reset: it stays out of use until the technician has seen it.
A manual can give a reset in one of two ways:
- At the mode selector: the door set to off and back to automatic, or a reset key or button on the selector, as the manual describes.
- At the board: the door switched off at its breaker and back on, where the manual says so. Where a backup battery is fitted, the manual says whether it is disconnected too, and how. If that means opening the operator cover, the reset at the board is the technician’s, because on battery the door keeps its power.
Before the door comes back on, the doorway is clear and people are kept back: a door can move on its own as it starts up again.
If the fault comes back, the reset has not fixed it. A door that needs resetting again and again has a fault the reset is hiding: it comes out of use, as above, and the call carries the fault code and what the door did before each reset.
Can automatic doors be opened manually?
Some can, and the door decides how: not every automatic door can be pushed open by hand, and the way a particular door opens by hand is in its manual, which its installer can show at handover. Where the manual allows a manager to open the door by hand, it is done in this order:
- The door stopped, with nobody in the doorway.
- The power off at the board, at the door’s breaker, so that the door cannot start when the power comes back. A door set to open by itself when the power fails can move as the breaker goes off.
- The backup battery disconnected, where one is fitted. On battery, the door can still move. If disconnecting it means opening the operator cover, the door is left to the technician.
- Only then the door’s own lock or release, as its manual describes, and the leaves moved by hand without forcing them.
- Afterwards, the release re-engaged and the lock reset before the breaker and the battery come back on. A door left on its release looks like a failed operator.
A revolving door is never forced round by hand against its drive.
The rules look at the same question from the exit side. As at October 2026, Portugal’s fire-safety regulation for buildings (the RT-SCIE, art. 54.º, n.º 3) does not count, among the exits usable in a fire, exits fitted with motorised doors or access-control obstacles, unless, if the power or the control system fails, they open automatically by sliding, retracting or rotating and free the whole width of the opening, or can be pushed open by hand in the direction of escape, swinging through at least 90°.
As at October 2026, whether a particular door counts as one of a building’s exits, how many exits are needed and how wide they must be are matters for the building’s fire-safety design: the SCIE project or, for the lowest risk category, the fire-safety sheet (ficha de segurança). ANEPC is the authority, and the câmara municipal for buildings in the 1st risk category.
As at October 2026, for workplaces, Portugal’s minimum safety and health rules (Portaria n.º 987/93) say that mechanically operated doors and gates must have emergency stop devices that are easy to identify and reach, and must be able to open automatically or by manual command if the power fails. The Portaria sets a separate regime for workplaces that already existed when it was made.
None of this says whether a particular door is an exit or must open in one of those ways. Ask the installer what this door does if the power or the control system fails, and ask whoever holds the building’s fire-safety documents whether its design counts the door as an exit.
What should a manager ask before signing a maintenance contract?
A maintenance contract is judged by what it writes down. Before signing, ask:
- Which doors does it cover, each named by make, model and place, and are the barriers, bollards or roller doors on the same record?
- What interval does each door’s manual set, and do the visits follow it?
- What is tested at each visit, door by door, and are the safety tests (the door stopping and reversing for a person, the sensors covering its path) written into the record?
- How is a breakdown reported, how is a door stuck shut on a way out or unable to lock treated compared with a noisy one, and how is a call-out out of hours charged?
- Which parts are included, which are quoted separately, and can parts for this operator still be had?
- What is left out: broken glass, damage from a vehicle or a trolley, misuse?
- What does the record show after each visit, from what was tested and found to what was replaced and what is advised next, and who keeps it?
- Will staff be shown the mode selector, the reset the manual allows and the order for opening the door by hand, and who holds the keys to the selector and the release?
- How does the contract end, and what notice does it need?
In a building of flats, the building’s administrador brings the contract to the condominium to decide on.
As at October 2026, where a building’s self-protection measures apply, Portugal’s fire-safety regulation for buildings, the RT-SCIE, requires escape routes to be kept usable at all times, and the upkeep of the technical installations, devices, equipment and systems in that use to follow programmes with set calendars and lists of periodic checks (RT-SCIE, art. 202.º).
As at October 2026, where Portugal’s law on work equipment (Decreto-Lei n.º 50/2005) applies, it requires the employer to have equipment liable to dangerous deterioration verified periodically by a competent person and to keep the reports; it fixes no interval and does not name doors or barriers. Whether the fire-safety programmes or the work-equipment checks reach a particular building or door is a question for whoever holds the building’s fire-safety documents and, at a workplace, for the employer.
What to send for a quote
A fault on an automatic door is diagnosed at the door, and a clear request narrows down the cause before anyone comes out. The page on automatic door servicing in the Algarve sets out what a service visit covers and how the quote works, which Handyman Algarve gives free, in English or Portuguese, from:
- what the door does, in one line, and since when;
- a short video of the fault, filmed from outside the door’s path;
- a photo of the mode selector, and of the operator’s label if it can be read from the floor, never from a ladder;
- any fault code the selector or a display shows;
- the type of door, sliding, swing or revolving, and how many leaves;
- whether people use it to leave the building, and whether it is out of service now;
- whether a maintenance contract covers it;
- whether it serves a hotel, a shop, a clinic or a building of flats;
- the town.
A request marked urgent is treated as one. We reply within one business day, usually much faster.
Get the number for your own job
Every price on this page depends on details only your job has. Describe it to Handyman Algarve, add a photo, and the quote comes back with the figure for that job, at no cost.
Free and without obligation.