Handyman Algarve quotes four kinds of automatic entrance work for hotels, shops and condominiums in the Algarve, as of 2026: automatic doors, whether sliding, swing or revolving; barriers and bollards for car parks and entrances; access control and intercoms for buildings; and motorised shopfront and industrial doors. Each is installed, serviced and repaired with the safety devices tested as part of the job, and the quote is free, in English or Portuguese.
How does an automatic door work?
An automatic door is a door moved by a motor instead of a hand. It opens when something tells it to, a sensor that sees a person coming, a push button, a card or a code, and it closes again on its own once the opening is clear.
The operator, in the housing above the door or on its frame, holds the motor and the drive: on a sliding door a belt moves the carriages the leaves hang from along a track, on a swing door an arm pushes the leaf, and a revolving door's wings are turned by a drive of their own. The control unit decides when the door opens, how long it stays open and what it does when a sensor sees something in its path.
The sensors do two jobs. Activation sensors open the door for someone approaching. Safety sensors watch the closing path and, on a swing door, the area the leaf sweeps, so that the door stops or reverses rather than closing on a person. The mode selector, a switch or a keyed panel, sets how the door behaves, from fully automatic to closed and locked. Some doors also carry a lock in the operator and a backup battery. A fault in any one of these parts can look like a failed motor, which is why a repair starts with the whole door and not with the motor.
Sliding, swing or revolving: which suits the entrance?
For a hotel, a shop, a clinic or a condominium lobby, the choice is made at the entrance, from the space beside and in front of the opening and from the way people move through it.
| Sliding | Swing | Revolving |
|---|
| Where it suits | Hotel and shop entrances, clinic receptions, condominium lobbies | A single doorway, an inner door, a narrow frontage, the door beside a revolving door | A hotel lobby where draughts, noise and the air conditioning matter |
|---|
| Space it needs | Wall beside the opening for the leaves to move along, and room above it for the operator; nothing swings into the room | Clear floor where the leaf opens, kept free of people and furniture, with the hinge side kept clear too | A large round footprint, and room for a separate door beside it |
|---|
| Traffic | People coming and going at the same time, with luggage, trolleys or a pushchair | A single doorway taken one direction at a time | A steady flow both ways, with the drum keeping draughts out as it turns |
|---|
| What to ask about an escape route | What it does if the power or the control system fails, and whether the building's fire-safety design counts it as an exit | Which way it opens, and whether it can be pushed open by hand in the direction of escape if the power fails | Whether the building's fire-safety design counts it as an exit, and where the door beside it is |
|---|
Whatever the type, a door that people use to leave the building raises one question before any other: what it does if the power or the control system fails. The answer is in the operator's settings and its manual, and whether the door counts as one of the building's exits is for the building's fire-safety design, as the rules further down this page set out.
Which suits a car park entrance: a barrier, a bollard or a gate?
The car park of a hotel, a resort or a building of flats can be closed in three ways, and each stops something different. A barrier lowers an arm across the lane. A rising bollard lifts a post out of the ground. A gate closes the whole entrance, to cars and to people on foot.
| Barrier | Rising bollard | Gate |
|---|
| What it stops | A car, with an arm across the lane; it controls access and is not a crash barrier | A car, with a post that rises from the ground; lowered, the entrance looks open | Cars and people on foot, over the full width of the entrance |
|---|
| Footprint and works | A cabinet beside the lane on its own foundation, a cable to it, and signs or lights where the lane needs them | Excavation for the housing, drainage so water cannot stand in it, and a cable | A clear run beside the wall for a sliding gate, or room to open into for a swing gate |
|---|
| People on foot | Their own path beside the lane: nobody walks or cycles under the boom | Kept off it: a rising bollard can lift under a person | Closed out too, unless a pedestrian door is part of the gate or beside it |
|---|
| Throughput | Built for one car after another at a lane | The post goes down for a car and rises again behind it: ask how it handles cars arriving one after another | Opens its whole width for each car, so it suits an entrance with fewer passes than a car park lane |
|---|
| What to ask about a power cut | How the boom is raised by hand, who holds the release key, and whether a backup battery is fitted | Whether it goes down or stays up, how it is lowered by hand, and who holds the key or the release | How it is released by hand, and who keeps the key |
|---|
In a building of flats the request comes through the building's administrador, and the quote is written for the condominium to decide on. Three questions belong in it: where people on foot will go, because a barrier lane is for vehicles; what happens in a power cut, and who holds the key or the release; and how residents and visitors will open it, which is the access control below.
Where a gate is the better answer, for example where the entrance has to be closed to people on foot as well, it is covered under electric gates and garage doors in the Algarve. For the two side by side in more detail, see how a barrier and a bollard differ, and which suits a car park.
A boom moves fast and low, and a bollard rises where people walk, so the rules on site are simple. Nobody walks or cycles under a boom or through a vehicle lane, and pedestrians use their own path. A barrier whose boom has been broken off or bent is left alone, with the power off at the board and the cabinet closed: the boom is balanced inside the cabinet, the balance is set for that boom, and the mechanism can move without the boom's weight on it. A backup battery, where one is fitted, sits in that cabinet and is left to the technician, and because the barrier can still run on it, no remote, keypad or button is used and the lane is kept clear until the technician has seen it.
A barrier's manual release, where the manual allows a manager to use it, goes in this order: the boom stopped, the power off at the board, the backup battery disconnected where one is fitted, then the release with its key, re-engaged afterwards before the breaker and the battery come back on.
A rising bollard can lift under a car or a person, so nobody stands on or over one. Lowering one by hand, with a hydraulic release or a key where the manual allows it, follows the same order: the bollard still, the power off at the board, the backup battery disconnected where one is fitted, then the release. The bollard then stays down and signed until the technician has seen it.
How does access control work on a building?
Access control decides who can open which door, gate or barrier, and when. At each entrance a reader identifies the person, by a card, a fob, a code typed on a keypad or a phone, and a controller checks whether that person is allowed in at that door at that hour and, if so, releases the lock or raises the barrier. The same system keeps the list of users, so a lost card is struck off the list rather than every lock being changed.
A building of flats has its own version of this in door entry: a panel at the street door with a button for each flat, a handset or a screen inside each flat, and the street door released from the flat. Video panels, and panels that ring a phone through an app, do the same job. A garage gate or a car park barrier can open by number plate, with a camera that reads the plate and opens for the plates on the building's list, by remote, or by phone. A house is a different job: its intercom or video doorbell is covered under home security, intercoms and video doorbells for a house.
Where residents open a gate or a barrier with a remote, the remote decides more than convenience. Gate remotes use one of two kinds of code. A fixed code does not change; on some models it is set with small switches to match the receiver. A rolling code changes each time the remote is used, and the receiver checks it. Manufacturers present rolling-code remotes as harder to copy than fixed-code ones. Their own documentation also explains how to copy a rolling-code remote, or pair a new one, from a remote that already works. A rolling code is no promise that a remote cannot be copied by whoever holds one.
Receiver manuals describe deleting remotes from the receiver's memory, and the method depends on the receiver: some delete a single remote by its memory position, some only with that remote in hand, and some can only erase every remote at once. If a remote goes missing, ask for it to be removed from the receiver's memory, not only for a new remote. On some receivers that means erasing every remote and pairing again the ones still in use. A remote that leaves with a former resident or a former member of staff still opens the entrance, and it is removed the same way.
How much does it cost to install an access control system?
As of 2026 it is priced per entrance and per cable route, not per reader, and a figure borrowed from another building misleads. What moves it: how many doors, gates and barriers are controlled; the reader at each, card, fob, code, phone or number plate; the lock or release each door needs; the controller, and how many users and time rules it holds; any app with a monthly fee; any door entry panel and the handsets in the flats; and the route the cable takes from each entrance back to the controller and to a supply. Two readers in one lobby and two entrances at either end of a car park are different jobs at the same count.
How to wire an access control system?
By the installer, from the manual and the drawings that come with the equipment: the cabling between the readers, the locks, the controller and the door entry panel follows them. The supply to the system, any new circuit and anything at the board is an electrician's work, covered under an electrician for the supply and the circuit. What a building can do before the quote is show the route: where the controller can sit, where the board is, and how a cable can get from each entrance to both.
What does motorising a shopfront or warehouse door add?
Shops close with roller grilles and roller doors. Warehouses and loading bays use sectional doors, whose panels run up and back under the ceiling, and fast doors, flexible curtains that rise and fall quickly between a loading bay and the store behind it. A roller shutter or a grille is made to the opening by a metalworker, and the shutter itself, with what sets its price, is covered under roller shutters, grilles and steelwork. This section covers what the motor brings with it.
Motorising a door adds four things to the job: the motor, sized to the weight of the curtain or the door; its controls, whether a push button, a key switch, a remote or a reader; the safety devices, on the closing edge or across the opening, that stop or reverse the door when a person or a vehicle is in its way; and a supply from the board, which is an electrician's work. Access control then decides who can open it and when: a key switch for the manager, a card or a code for staff, a time rule that keeps a loading bay shut after hours.
A roller door or a grille whose spring or drive has failed can drop. If one has stuck part open or comes down crooked, keep people out from under it, do not pull it down by hand and do not run the motor again, from the button, the key switch or a remote, or at the reader. Switch the power off at the board, at the door's breaker, if reaching the board does not mean passing under the curtain; the backup battery, where one is fitted, is left to the technician, because reaching it can mean climbing up to the box, beside the open curtain. Nobody climbs up to the box. The springs in the barrel are under tension, and releasing or replacing them is a technician's job, done with the curtain secured.
Send a photo taken from the ground and mark the request as urgent: a request marked urgent is treated as one.
What does a maintenance visit on an automatic door check?
A visit tests the safety devices first: that the door stops and reverses for a person in its path, and that the safety sensors cover the whole closing path and, on a swing door, the sweep of the leaf. It then checks the activation sensors, the drive (the belt, the carriages and the track, or the arm), the floor guide, the lock and the manual release, the mode selector, the backup battery where one is fitted, and the fixings of the operator and the leaves.
On a barrier it checks the boom and its balance, and on a bollard the rise and fall and the drainage under it. The interval between visits is set by the installation's own manual, and each visit goes into the service record.
What should a maintenance contract say?
In writing: the visits, at the interval the manual sets; what is tested at each one; how a breakdown call-out is handled and how it is charged; whether parts are included or quoted separately; and where the record of each visit is kept. A hotel or a shop with several doors, barriers and bollards can put them all on one contract, so that one record shows the whole entrance.
As at October 2026, where a building's self-protection measures apply, Portugal's fire-safety regulation for buildings, the RT-SCIE, requires escape routes to be kept usable at all times, and the upkeep of the technical installations, devices, equipment and systems in that use to follow programmes with set calendars and lists of periodic checks (RT-SCIE, art. 202.º). Whether those measures apply to a building, and what its programme lists, is a question for whoever holds its fire-safety documents.
What moves the cost of a repair?
What has failed, and whether the part can be had: a sensor, a belt or a carriage wheel, the control unit, the motor, the lock or the battery are different lines. The make and the age of the door matter as much as the fault, and the brand matters less than whether parts and a technician for it can be had locally. Access adds to it, from an operator above a tall glazed entrance to a visit after closing time so that a hotel or a shop is not left without its door. Broken glass is a separate line, and a call-out under a maintenance contract is priced by the contract's own terms.
What should a manager do when an automatic door misbehaves?
A door that moves when it should not, does not stop or reverse for a person, closes too fast or bangs is taken out of use: keep people clear, put it out of service with its own mode or key switch if it has one, and otherwise switch it off at the board and disconnect the backup battery where one is fitted, as the manual shows. Where the battery sits inside the operator, under its cover, it is left to the technician and people are kept clear of the door. Then call. Nobody puts a hand near the belt, the pulleys or the carriage under the operator cover, the cover stays closed, and nobody climbs up to the operator.
A sensor is never bridged, covered, taped or disconnected to keep a door running: disconnecting a sensor to get a door moving again is not a temporary fix, because it leaves the door free to close on whoever is in the way.
A door that people use to leave the building is never left locked shut or out of action while the building is occupied without another exit open. If it has to come out of service, it is left open where security allows, or another way out is kept open and signed, and the person who holds the building's fire-safety documents is told. What sits behind each symptom, and what a manager can check from the floor before calling, is set out in common problems with automatic doors, and what a manager can check.
What do the rules say about automatic doors and barriers?
As at October 2026, the European Commission's guidance on the Machinery Directive gives powered gates and doors as examples of machinery installed in buildings. In that guidance, the manufacturer of such machinery is responsible for its conformity, affixes the CE marking and signs the EC declaration of conformity, and the person who installs it is responsible for carrying out the manufacturer's installation instructions. The CE marking on machinery is affixed by the manufacturer itself: it is the manufacturer's declaration, not a certificate issued by an independent body. The Directive reached Portuguese law through Decreto-Lei n.º 103/2008, since amended.
The same guidance says that machinery assembled on site must still go through conformity assessment and carry the CE marking before it is first put into service, and that where several firms take part, one of them must take responsibility as the manufacturer. If your door was assembled on site, you can ask the installer whether it came with an EC declaration of conformity and which firm the declaration names as manufacturer. Where a door, barrier or turnstile comes with an EC declaration of conformity, you can ask the installer for a copy: where harmonised standards were used, the declaration refers to them.
As at October 2026, the European standard for power-operated pedestrian doors, EN 16005 ('Power operated pedestrian doorsets - Safety in use - Requirements and test methods'), is listed in its EN 16005:2023+A1:2024 edition in the Official Journal of the EU under the Machinery Directive. The decision that publishes this list is repealed with effect from 20 January 2027, when the Directive is replaced.
As at October 2026, CEN, the European standards body, describes a different standard, EN 12453, as covering power-operated doors, gates and barriers whose main intended use is access for goods and vehicles, accompanied or driven by persons, in industrial, commercial or residential premises, and also rolling shutters and rolling grilles used in shops mainly to protect goods. Its description excludes horizontally moving power-operated doors mainly for pedestrians, railway barriers, barriers solely for pedestrians and barriers used solely for vehicles on motorways.
Under the Machinery Directive, which applies until 19 January 2027, machinery built to a harmonised standard whose reference is published in the Official Journal is presumed to meet the essential health and safety requirements that the standard covers, and only those. The European Commission's guidance adds that this presumption is not absolute and does not affect the authorities' duty to check that products really comply.
As at October 2026, no list of harmonised standards under the new Machinery Regulation had been published in the Official Journal: the European Commission says the first one is being prepared. From 20 January 2027 the EU Machinery Regulation (EU) 2023/1230 applies in place of the Machinery Directive. The European Commission says that machinery placed on the EU market before that date must comply with the Directive.
As at October 2026, Portugal's fire-safety regulation for buildings (the RT-SCIE, art. 54.º, n.º 3) does not count, among the exits usable in a fire, exits fitted with motorised doors or access-control obstacles, unless, if the power or the control system fails, they open automatically by sliding, retracting or rotating and free the whole width of the opening, or can be pushed open by hand in the direction of escape, swinging through at least 90°.
Whether a particular door counts as one of a building's exits, how many exits are needed and how wide they must be are matters for the building's fire-safety design: the SCIE project or, for the lowest risk category, the fire-safety sheet (ficha de segurança). ANEPC is the authority, and the câmara municipal for buildings in the 1st risk category.
As at October 2026, doors that more than 50 people can use must open easily in the direction of escape, must not need bolts or other locks undone while the premises are open, and must have signs showing how to operate them (RT-SCIE, art. 62.º, n.º 1). How many people can use a door comes from the building's fire-safety design.
The rule against needing to undo bolts or locks while the premises are open has two exceptions in the RT-SCIE (art. 62.º, n.º 4, as at October 2026). It does not apply to doors in places for psychiatric treatment, or in places where people's access to the outside must be controlled, if those places are under permanent watch and the doors' immediate opening is assured when needed. Nor does it apply, in the uses numbered VI to XI (whose legal descriptions include hotels, restaurants and shops), to doors whose use other than in an emergency could undermine the control that running those premises requires, if the doors have signposted automatic and manual controls that open them immediately when needed.
Portugal's fire-safety law subjects buildings to regular inspections of their fire-safety conditions as a whole, within at most six, five, four or three years according to the building's risk category. Buildings of the 1st risk category in every use except types IV and V, and residential-only buildings of the 2nd category, are exempt from regular inspection (Decreto-Lei n.º 220/2008, art. 19.º). These inspections concern the building; neither that decree nor the RT-SCIE fixes an inspection interval specific to automatic doors (as at October 2026).
As at October 2026, for doors on the accessible route of the buildings it covers, Portugal's accessibility law (Decreto-Lei n.º 163/2006) allows automatic doors opened by motion detectors or by operating devices such as a mat or switches. It requires them to have protective handrails («corrimãos de protecção») and horizontal or vertical sensors, and to be programmed to stay fully open until the doorway is completely clear. These are design and construction rules. On an accessible route, revolving doors and turnstiles are allowed only if there is an accessible alternative door or passage next to them and in use (Decreto-Lei n.º 163/2006, annex, 4.9.4).
As at October 2026, in the car parks it covers, the accessibility law requires the controls of automatic closing and opening systems, such as barriers and gates, to be operable by a person with reduced mobility from inside a car (Decreto-Lei n.º 163/2006, annex, 2.8.4). None of this decides whether a particular door, barrier or entrance complies: that question goes to the installer, the declaration of conformity and the building's fire-safety design.